Help

Edit device settings

How to work through the full per-device settings dialog, including all tabs, permissions, and update validation.

Who is this for

Device managers who need to inspect or update one device through the full Settings dialog.

Outcome

You can open the complete tabbed device settings dialog, understand which tabs are available for the selected device, and save valid changes in one update flow.

Before you start

  • You are signed in.
  • You have access to the group containing the device.
  • Device settings action is visible for the device type/scope.

What opens in this dialog

The Settings action opens one multi-tab dialog. The visible tab row depends on device type, partner rules, connectivity/backend path, and your rights.

Possible tabs:

  • General
  • Downlink
  • Sigfox
  • Processing parameters
  • Custom view
  • Calibrations
  • Meta data

In some cases the dialog is restricted:

  • some tabs are hidden because the current group access does not allow them,
  • only Close is available when editing is not allowed,
  • forbidden device types show an information message instead of editable content.

Steps

  1. Open a device card or row.
  2. Open the device menu.
  3. Click Settings.
  4. Wait until the dialog loads both the device and the device type configuration.
  5. Review the available tabs.
  6. Edit only the tabs relevant to your task.
  7. Click Update only after all edited fields are valid.
  8. Verify the success message and the refreshed device state after the dialog closes.

Tab-by-tab guide

General tab

Use this tab for the core device profile.

What you can review or change:

  • device ID (read-only),
  • device name,
  • manufacturer,
  • device type,
  • radio zone,
  • group path (read-only),
  • location source preference,
  • fixed latitude/longitude,
  • timezone,
  • description.

Important behavior:

  • Device name is editable only with visual update access.
  • Manufacturer, device type, radio zone, location settings, timezone, and description are editable only with device update access.
  • Without the corresponding update right, fields are disabled rather than appearing editable. If neither update right is available, the dialog offers only Close.
  • Name requires 3-30 characters.
  • Changing manufacturer narrows the available device types.
  • Changing device type triggers a confirmation and resets type-dependent sections such as downlink/custom-data defaults.
  • Latitude and longitude are editable only when location source is Fixed location/static.
  • Group path is shown for orientation and is not editable.

Downlink tab

This tab is shown with Downlink Read permission. Downlink access is independent from permission to edit general device settings.

What you can do:

  • review the pending and last downlink with Downlink Read permission,
  • enter or replace a pending payload with Downlink Update permission,
  • clear the currently pending payload with Downlink Delete permission,
  • repeat the last downlink with Downlink Update permission.

Important behavior:

  • Downlink must contain hexadecimal characters only.
  • Setting a payload requires a non-empty value. Clearing uses the explicit Clear action.
  • Some device types do not support downlink at all; in that case the tab shows an informational message instead of an editor.

Sigfox tab

This tab is shown only when backend access is allowed and the current connectivity path is eligible for backend inspection.

What you can review:

  • device ID,
  • PAC,
  • backend state,
  • LQI,
  • last seen,
  • creation time,
  • activation time,
  • token detail message.

This tab is read-only and is mainly used for troubleshooting differences between device state in the application and state in the backend.

Processing parameters tab

This tab is shown only when the selected device type defines a custom-data schema and you have device update rights.

What you can do:

  • inspect and edit type-specific processing parameters,
  • update the custom data payload used by parsing/processing logic.

Important behavior:

  • Validation depends on the schema defined for the device type.
  • Invalid schema-driven content can fail during update even if the rest of the dialog is valid.

Custom view tab

This tab is shown only when you have visual update rights.

What you can configure:

  • active device view mode,
  • graph scale,
  • selected chart,
  • main key,
  • default zoom level,
  • number of tracing positions,
  • dashboard keys,
  • active-alert visibility.

Important behavior:

  • Only visible/enabled dashboard keys are saved back into the device view config.
  • Changes here affect how the device appears in visual dashboards and map/tracing contexts.

Calibrations tab

This tab is shown only when you have device update rights.

What you can do:

  • add calibration rows,
  • remove calibration rows,
  • select probe,
  • enter current and reference values,
  • set tolerance,
  • store technician, equipment, date, and comment.

Important behavior:

  • Probe selection drives unit lookup and refreshes current value.
  • Measurement error is calculated from reference and current values.
  • Status depends on whether the error stays inside the tolerance range.

Meta data tab

This tab is partner-specific. In the current implementation it is shown only for the Anticimex partner and requires visual update rights.

Use it when your deployment exposes extra metadata fields for that partner-specific workflow.

Update behavior

The dialog uses one shared Update action for all editable tabs.

What to expect:

  • Update is enabled only when at least one editable field is dirty and no dirty field is invalid.
  • If invalid data exists, the dialog shows a validation warning.
  • One update saves basic data, location, custom data, metadata, downlink values, custom view, and calibrations together.
  • If you try to update with invalid data, the dialog automatically switches to the first tab containing the invalid control and focuses the first invalid field.

Practical checks

  • The dialog loads the selected device, not a stale previous device.
  • The visible tab row matches current rights and device capabilities.
  • General tab enables latitude/longitude only for fixed location.
  • Device type change updates dependent type-based sections.
  • Downlink tab blocks empty or non-hexadecimal payloads when setting a pending command.
  • Sigfox tab shows backend values only when backend access is available.
  • Calibration rows compute measurement error and tolerance status after data entry.
  • Update becomes enabled only after a real valid change.
  • Saved changes are visible after the dialog closes.

Common issues

  • Settings action missing: verify device menu permissions.
  • Device type forbidden: the dialog shows an information message and does not allow editing in this white-label context.
  • Update button stays disabled: there may be no dirty change yet, or one edited field is invalid.
  • Save rejected: check device type constraints, schema validation, or invalid field values.
  • Downlink tab missing: downlink rights or device capability may be missing.
  • Processing parameters tab missing: current device type may not define a custom data schema.
  • Sigfox tab missing: backend access or current connectivity path may not allow it.
  • Meta data tab missing: it is partner-specific and not globally available.
  • Wrong device opens: reselect the device and retry.

Related use cases

Support handoff

If the dialog fails, include content_id, device id, group id, affected tab name, edited fields, whether Update stayed disabled or failed after submit, and any validation/error message shown.